帮忙翻译一下一篇文章(中翻英),谢谢
- 提问者网友:疯孩纸
- 2021-04-29 15:13
1、节电器组成:感应器A、发射器B、接收控制器C。
2、工作原理:感应器A、发射器B分别安装于观景阳台门固定侧与活动侧上,接收控制器C接于空调冷冻水二通阀电源回路中。当阳台门打开,感应器A感应与发射器B超出一定距离(约1~2cm)时,发射器B发射信号至接收控制器C 上,通过电路转换控制二通阀回路断开,二通阀关闭,从而停止空调换热。反之,当阳台门关闭,感应器A、发射器B重新合并,发射器B发射信号至接收控制器 C,通过电路转换控制二通阀回路接通,空调恢复正常工作。对于新建酒店,本公司另有一款有线节电器,酒店装修时可预先埋设线路,使数据传输更稳定。
3、节电分析(以大梅沙喜来登酒店为例):现客房每间标准间风机盘管的制冷量为5780瓦(约合1.6冷吨)。按照正常夏季室外温度为33℃计算,白天每小时耗电量为1.8度/每间房,且不算盘管机本身耗电,正常工作情况下室内温度达到设定温度时,风机及电磁阀关闭。房间温度处于设定的饱和状态时,每小时的耗电量为0.8至1度/每间房,甚至更低一些。当客人在房间将阳台门打开时,室外热空气只需要五分钟时间就可以将室内的舒适温度升高到30℃。此时房间内的空调将以最大负荷运转,且对室内温度起不到一点的降温效果。如未安装节电器,将会出现下列不良情形: ☆ 每间房每天每开一次阳台门超过五分钟,就可以浪费0.5度电以上,如果按400间房平均每间房每天只开一次阳台门,那么就可以浪费200度电,如果阳台门开半个小时到一小时以上,冷热交换就可浪费4度电,如果400间房平均每天开一次阳台门达半小时,就一次性浪费1200至1600度电,且是在很短的时间内。如果有多次开门的情况,浪费就更大了。大量超负荷的冷热交换也会造成冷冻主机的使用寿命降低。 ☆ 经常开门因温差的原因将造成空调风口产生冷凝水,影响美观,且客人容易投拆。 ☆ 因空调风口是木制品,长期有冷凝水容易使木头发黑及发霉.造成经常维修和成本上升。一家酒店400间房平均每天只打开阳台门半个小时即浪费1200度电,一个月将浪费36000度电。若全部安装三友联公司发明的节电器后,按电价1元/度算,半年将节省电费21.6万元,约5~6个月便可收回成本。三友联公司已为深圳大梅沙喜来登酒店、京基假日海湾大酒店、惠州巽寮金海湾喜来登酒店等安装了中央空调末端智能节电器,并取得极佳的节能效果,深受客户的好评。 深圳大梅沙喜来登酒店,安装节电器400套 深圳京基假日海湾大酒店,安装节电器300套 惠州巽寮金海湾喜来登酒店,安装节电器320套<!-ad->
- 五星知识达人网友:轻熟杀无赦
- 2021-04-29 16:52
: Central air-conditioning end of the smart power-saving controller - an "observation Hotel" energy-saving new weapons almost all of the viewing hotels (including sea, lake, mountain, etc.) will encounter this problem: When the guests open viewing balcony door, a large number of hot and humid outdoor air flow room, but the indoor air-conditioning work as usual, resulting in energy waste, while a vent condensation caused by air-conditioning, affecting appearance, leading to customer complaints. If the majority of rooms are also open balcony door, will cause the entire central air-conditioning system load increase, return water temperature, central air conditioning can cause the vicious consequences of the host surge. 3 Union Energy Technology Co., Ltd. invention patent product (patent number: ZL200920236600.2) Central air-conditioning end of the Smart Saver (hereinafter referred to as "saving"), can effectively solve this problem, significantly for the hotel save energy, reduce electricity expenditures.
1、节电器组成:感应器A、发射器B、接收控制器C。
:Saver consists of: sensor A, transmitter B, receive controller C.
2、工作原理:感应器A、发射器B分别安装于观景阳台门固定侧与活动侧上,接收控制器C接于空调冷冻水二通阀电源回路中。当阳台门打开,感应器A感应与发射器B超出一定距离(约1~2cm)时,发射器B发射信号至接收控制器C 上,通过电路转换控制二通阀回路断开,二通阀关闭,从而停止空调换热。反之,当阳台门关闭,感应器A、发射器B重新合并,发射器B发射信号至接收控制器 C,通过电路转换控制二通阀回路接通,空调恢复正常工作。对于新建酒店,本公司另有一款有线节电器,酒店装修时可预先埋设线路,使数据传输更稳定。
:the working principle of: sensor A, respectively B transmitter installed in the viewing balcony door on the side of the fixed side and activities, receive controller C connected to two-way valve air-conditioning chilled water supply loop. When the balcony door open, sensor A sensor and transmitter B beyond a certain distance (about 1 ~ 2cm), the emission signal transmitter B to the receiving controller, C, through the circuit change of control of two-way valve circuit disconnect, two-way valve closed, in order to stop air-conditioning heat exchangers. On the contrary, when the balcony doors closed, sensor A, transmitter B to re-merge, B emission signal transmitter to the receiving controller C, via the circuit switching control circuit connected to two-way valve, air-conditioning to resume normal work. In new hotels, a cable company while saving the hotel renovation can be pre-laid lines, so that data transmission more stable.
3、节电分析(以大梅沙喜来登酒店为例):现客房每间标准间风机盘管的制冷量为5780瓦(约合1.6冷吨)。按照正常夏季室外温度为33℃计算,白天每小时耗电量为1.8度/每间房,且不算盘管机本身耗电,正常工作情况下室内温度达到设定温度时,风机及电磁阀关闭。房间温度处于设定的饱和状态时,每小时的耗电量为0.8至1度/每间房,甚至更低一些。当客人在房间将阳台门打开时,室外热空气只需要五分钟时间就可以将室内的舒适温度升高到30℃。此时房间内的空调将以最大负荷运转,且对室内温度起不到一点的降温效果。如未安装节电器,将会出现下列不良情形: ☆ 每间房每天每开一次阳台门超过五分钟,就可以浪费0.5度电以上,如果按400间房平均每间房每天只开一次阳台门,那么就可以浪费200度电,如果阳台门开半个小时到一小时以上,冷热交换就可浪费4度电,如果400间房平均每天开一次阳台门达半小时,就一次性浪费1200至1600度电,且是在很短的时间内。如果有多次开门的情况,浪费就更大了。大量超负荷的冷热交换也会造成冷冻主机的使用寿命降低。 ☆ 经常开门因温差的原因将造成空调风口产生冷凝水,影响美观,且客人容易投拆。 ☆ 因空调风口是木制品,长期有冷凝水容易使木头发黑及发霉.造成经常维修和成本上升。一家酒店400间房平均每天只打开阳台门半个小时即浪费1200度电,一个月将浪费36000度电。若全部安装三友联公司发明的节电器后,按电价1元/度算,半年将节省电费21.6万元,约5~6个月便可收回成本。三友联公司已为深圳大梅沙喜来登酒店、京基假日海湾大酒店、惠州巽寮金海湾喜来登酒店等安装了中央空调末端智能节电器,并取得极佳的节能效果,深受客户的好评。 深圳大梅沙喜来登酒店,安装节电器400套 深圳京基假日海湾大酒店,安装节电器300套 惠州巽寮金海湾喜来登酒店,安装节电器320套<!-ad-> :
power-saving analysis (in order to Dameisha Sheraton as an example): Each standard room is room fan coil cooling capacity of 5780 watts (about 1.6 cooling tons). According to the normal outdoor temperature was 33 ℃ in summer terms, the power consumption of 1.8 degrees per hour during the day / per room, and does not power abacus tube machine itself, the normal working conditions under which the indoor temperature reaches the set temperature, fan and solenoid valve closed. Room temperature at a set of saturation, the hourly power consumption 0.8 to 1 ° / per room, or even lower. When the guests in the room to the balcony door open, outdoor hot air only five minutes you can be comfortable indoor temperature to 30 ℃. At this point the room air-conditioning will be the biggest load operation, and a little on the indoor temperature pleasant cooling effect. If not install the Power Saver, will be the following adverse conditions: ☆ per room per day once the balcony door more than five minutes, you can waste more than 0.5 kWh, if the room at 400 per room per day on average only once a the balcony door, it can be a waste of 200 units of electricity, if the balcony door open for more than half an hour to an hour, hot and cold switching can be a waste of 4 units of electricity, if the daily average of 400 rooms to open the door for half an hour once a balcony on the one-time a waste of 1200-1600 units of electricity, and is in a very short period of time. If there are multiple open the case, waste is even greater. Overload the exchange of a large number of hot and cold can also cause frozen to reduce the life of the host. ☆ often open the door because of the reasons for difference in temperature will cause condensation of water produced air-conditioning vent, affecting appearance, and the guests easy to bring complaints. ☆ a result of air-conditioning vent is a wooden products, long term condensate is easy for the black and moldy wood. Caused by the regular maintenance and costs. A hotel room an average of 400 to open the balcony door for half an hour a day that is a waste of 1200 units of electricity a month would be a waste of 36,000 kWh. If all three Union's installation, after saving the invention, according to price 1 yuan / degree calculation, for half a year will save electricity 216,000 yuan, about 5 ~ 6 months to recover the costs. 3 Union Company has Dameisha Sheraton Hotel in Shenzhen, Beijing-based Holiday Inn Bay View Hotel, Huizhou Xunliao Golden Bay Sheraton hotels, central air conditioning installed in the end of Smart Saver and achieved excellent energy-saving effect, deeply customer high praise . Dameisha Sheraton Hotel in Shenzhen, installation Saver 400 sets of Shenzhen Bay Hotel Holiday Inn Beijing-based installation Saver 300 sets Xunliao Golden Bay Sheraton Hotel in Huizhou, installation Saver 320 sets <!-Ad-> | ||
- 1楼网友:何以畏孤独
- 2021-04-29 19:46
Central air-conditioning end of the smart power-saving controller - an "observation Hotel" energy-saving new weapons almost all of the viewing hotels (including sea, lake, mountain, etc.) will encounter this problem: When the guests open viewing balcony door, a large number of hot and humid outdoor air flow room, but the indoor air-conditioning work as usual, resulting in energy waste, while a vent condensation caused by air-conditioning, affecting appearance, leading to customer complaints. If the majority of rooms are also open balcony door, will cause the entire central air-conditioning system load increase, return water temperature, central air conditioning can cause the vicious consequences of the host surge. 3 Union Energy Technology Co., Ltd. invention patent product (patent number: ZL200920236600.2) Central air-conditioning end of the Smart Saver (hereinafter referred to as "saving"), can effectively solve this problem, significantly for the hotel save energy, reduce electricity expenditures. 1, Saver consists of: sensor A, transmitter B, receive controller C. 2, the working principle of: sensor A, respectively B transmitter installed in the viewing balcony door on the side of the fixed side and activities, receive controller C connected to two-way valve air-conditioning chilled water supply loop. When the balcony door open, sensor A sensor and transmitter B beyond a certain distance (about 1 ~ 2cm), the emission signal transmitter B to the receiving controller, C, through the circuit change of control of two-way valve circuit disconnect, two-way valve closed, in order to stop air-conditioning heat exchangers. On the contrary, when the balcony doors closed, sensor A, transmitter B to re-merge, B emission signal transmitter to the receiving controller C, via the circuit switching control circuit connected to two-way valve, air-conditioning to resume normal work. In new hotels, a cable company while saving the hotel renovation can be pre-laid lines, so that data transmission more stable. 3, power-saving analysis (in order to Dameisha Sheraton as an example): Each standard room is room fan coil cooling capacity of 5780 watts (about 1.6 cooling tons). According to the normal outdoor temperature was 33 ℃ in summer terms, the power consumption of 1.8 degrees per hour during the day / per room, and does not power abacus tube machine itself, the normal working conditions under which the indoor temperature reaches the set temperature, fan and solenoid valve closed. Room temperature at a set of saturation, the hourly power consumption 0.8 to 1 ° / per room, or even lower. When the guests in the room to the balcony door open, outdoor hot air only five minutes you can be comfortable indoor temperature to 30 ℃. At this point the room air-conditioning will be the biggest load operation, and a little on the indoor temperature pleasant cooling effect. If not install the Power Saver, will be the following adverse conditions: ☆ per room per day once the balcony door more than five minutes, you can waste more than 0.5 kWh, if the room at 400 per room per day on average only once a the balcony door, it can be a waste of 200 units of electricity, if the balcony door open for more than half an hour to an hour, hot and cold switching can be a waste of 4 units of electricity, if the daily average of 400 rooms to open the door for half an hour once a balcony on the one-time a waste of 1200-1600 units of electricity, and is in a very short period of time. If there are multiple open the case, waste is even greater. Overload the exchange of a large number of hot and cold can also cause frozen to reduce the life of the host. ☆ often open the door because of the reasons for difference in temperature will cause condensation of water produced air-conditioning vent, affecting appearance, and the guests easy to bring complaints. ☆ a result of air-conditioning vent is a wooden products, long term condensate is easy for the black and moldy wood. Caused by the regular maintenance and costs. A hotel room an average of 400 to open the balcony door for half an hour a day that is a waste of 1200 units of electricity a month would be a waste of 36,000 kWh. If all three Union's installation, after saving the invention, according to price 1 yuan / degree calculation, for half a year will save electricity 216,000 yuan, about 5 ~ 6 months to recover the costs. 3 Union Company has Dameisha Sheraton Hotel in Shenzhen, Beijing-based Holiday Inn Bay View Hotel, Huizhou Xunliao Golden Bay Sheraton hotels, central air conditioning installed in the end of Smart Saver and achieved excellent energy-saving effect, deeply customer high praise . Dameisha Sheraton Hotel in Shenzhen, installation Saver 400 sets of Shenzhen Bay Hotel Holiday Inn Beijing-based installation Saver 300 sets Xunliao Golden Bay Sheraton Hotel in Huizhou, installation Saver 320 sets <!-Ad-> |
- 2楼网友:煞尾
- 2021-04-29 18:51
- 3楼网友:狂恋
- 2021-04-29 17:38
Central air-conditioning end of the smart power-saving controller - an "observation Hotel" energy-saving new weapons almost all of the viewing hotels (including sea, lake, mountain, etc.) will encounter this problem: When the guests open viewing balcony door, a large number of hot and humid outdoor air flow room, but the indoor air-conditioning work as usual, resulting in energy waste, while a vent condensation caused by air-conditioning, affecting appearance, leading to customer complaints. If the majority of rooms are also open balcony door, will cause the entire central air-conditioning system load increase, return water temperature, central air conditioning can cause the vicious consequences of the host surge. 3 Union Energy Technology Co., Ltd. invention patent product (patent number: ZL200920236600.2) Central air-conditioning end of the Smart Saver (hereinafter referred to as "saving"), can effectively solve this problem, significantly for the hotel save energy, reduce electricity expenditures.
1, Saver consists of: sensor A, transmitter B, receive controller C.
2, the working principle of: sensor A, respectively B transmitter installed in the viewing balcony door on the side of the fixed side and activities, receive controller C connected to two-way valve air-conditioning chilled water supply loop. When the balcony door open, sensor A sensor and transmitter B beyond a certain distance (about 1 ~ 2cm), the emission signal transmitter B to the receiving controller, C, through the circuit change of control of two-way valve circuit disconnect, two-way valve closed, in order to stop air-conditioning heat exchangers. On the contrary, when the balcony doors closed, sensor A, transmitter B to re-merge, B emission signal transmitter to the receiving controller C, via the circuit switching control circuit connected to two-way valve, air-conditioning to resume normal work. In new hotels, a cable company while saving the hotel renovation can be pre-laid lines, so that data transmission more stable.
3, power-saving analysis (in order to Dameisha Sheraton as an example): Each standard room is room fan coil cooling capacity of 5780 watts (about 1.6 cooling tons). According to the normal outdoor temperature was 33 ℃ in summer terms, the power consumption of 1.8 degrees per hour during the day / per room, and does not power abacus tube machine itself, the normal working conditions under which the indoor temperature reaches the set temperature, fan and solenoid valve closed. Room temperature at a set of saturation, the hourly power consumption 0.8 to 1 ° / per room, or even lower. When the guests in the room to the balcony door open, outdoor hot air only five minutes you can be comfortable indoor temperature to 30 ℃. At this point the room air-conditioning will be the biggest load operation, and the indoor temperature