永发信息网

PT100测温仪的接线方法

答案:2  悬赏:70  手机版
解决时间 2021-04-03 20:15
  • 提问者网友:蔚蓝的太阳
  • 2021-04-03 13:06
PT100测温仪的接线方法
最佳答案
  • 五星知识达人网友:迟山
  • 2021-04-03 14:01
你好,我是专业做仪表的
首先你的问题提的不够完整,你需要提供你pt100是几线制的,2要告诉我你温控的型号。
如果有问题联系我吧,我的联系方式资料里有
全部回答
  • 1楼网友:洒脱疯子
  • 2021-04-03 15:07
英文水准不高哦 有问题可以交流一下哦 qq 474133512 ro; pt100 is platinic resistance, it will be the resistance of changes with the temperature of 100 namely after pt said it in 0 to 100 ohm resistance, resistance of the 100 it about 13.85 ohms its industrial principle: when pt100 at 0 celsius when his resistance to 100 ohms, its value will rise as the temperature uniform growth into medical, motor, industrial, temperature calculation, high temperature resistance calculation, application scope is very equipment widely common pt100 feeling temperature elements have ceramic components, glass components, mica components, they are respectively by platinum wire around the ceramic skeleton, glass frame, mica skeletons again by complex processing technology from film with vacuum deposition platinic resistance: the platinum sputtering film technology in ceramic substrate, film thickness in 2 microns with glass, within the ni (or sintering material, the pd) lead fixed made film components of laser adjustable resistance