在allegro导入网表时出现如下错误,是什么问题呀?之前在orcad原理图生成网表时已经OK了。

答案:2  悬赏:40  手机版
解决时间 2021-02-28 16:21
  • 提问者网友:遮云壑
  • 2021-02-28 01:48
(---------------------------------------------------------------------)
( )
( Netrev Allegro Import Logic )
( )
( Drawing : davinci.brd )
( Software Version : 16.3p004 )
( Date/Time : Fri May 03 22:03:38 2013 )
( )
(---------------------------------------------------------------------)

------ Directives ------

RIPUP_ETCH FALSE;
RIPUP_SYMBOLS ALWAYS;
Missing symbol has error FALSE;
SCHEMATIC_DIRECTORY 'I:/davincipcb/allegro';
BOARD_DIRECTORY '';
OLD_BOARD_NAME 'I:/davincipcb/davinci.brd';
NEW_BOARD_NAME 'I:/davincipcb/davinci.brd';

CmdLine: netrev -$ -i I:/davincipcb/allegro -y 1 I:/davincipcb/#Taaaaaa17952.tmp

------ Preparing to read pst files ------

Starting to read I:/davincipcb/allegro/pstchip.dat
Finished reading I:/davincipcb/allegro/pstchip.dat (00:00:00.08)
Starting to read I:/davincipcb/allegro/pstxprt.dat
Finished reading I:/davincipcb/allegro/pstxprt.dat (00:00:00.02)
Starting to read I:/davincipcb/allegro/pstxnet.dat
Finished reading I:/davincipcb/allegro/pstxnet.dat (00:00:00.02)

------ Oversights/Warnings/Errors ------

ERROR(SPMHUT-1): Illegal character(s) present in the name or value.

------ Summary Statistics ------

#1 Run stopped because errors were detected

netrev run on May 3 22:03:38 2013
DESIGN NAME : 'DAVINCIDM6446改1'
PACKAGING ON Nov 17 2009 03:09:43

COMPILE 'logic'
CHECK_PIN_NAMES OFF
CROSS_REFERENCE OFF
FEEDBACK OFF
INCREMENTAL OFF
INTERFACE_TYPE PHYSICAL
MAX_ERRORS 500
MERGE_MINIMUM 5
NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|'
NET_NAME_LENGTH 24
OVERSIGHTS ON
REPLACE_CHECK OFF
SINGLE_NODE_NETS ON
SPLIT_MINIMUM 0
SUPPRESS 20
WARNINGS ON

1 errors detected
No oversight detected
No warning detected

cpu time 0:00:32
elapsed time 0:00:00
最佳答案
  • 五星知识达人网友:上分大魔王
  • 2021-02-28 02:25
ERROR(SPMHUT-1): Illegal character(s) present in the name or value.

有非法字符,你查看看是不是某个零件脚名字是不是改动过?有空格,。,;‘等等之类的符号?
全部回答
  • 1楼网友:duile
  • 2021-02-28 03:53
这个是pin-number语法错误,因为里面有'..',你可以查看下最新画好的元件里,哪有元件的管脚编号里有'..'出现。
我要举报
如以上回答内容为低俗、色情、不良、暴力、侵权、涉及违法等信息,可以点下面链接进行举报!